BJQDR - ALKYD, SEMI-GLOSS, INTERIOR YELLOW 23711

  • MSDS: BJQDR
  • Manufacturer: CHEMRAY COATING CORP
  • Product Name: ALKYD, SEMI-GLOSS, INTERIOR YELLOW 23711
  • National Stock Number: 8010-00-616-0008
Product Identification

Product ID:ALKYD, SEMI-GLOSS, INTERIOR YELLOW 23711
MSDS Date:05/14/1990
FSC:8010
NIIN:00-616-0008
MSDS Number: BJQDR

Responsible Party
CHEMRAY COATING, CORP.
209 N. MICHIGAN AVENUE
KENILWORTH, NJ 07033
US

Emergency Phone: 800-924-9300, CHEMTREC-24 HRS

Info Phone: 201-245-1111

Preparer: FRED ARMSTRONG

Cage: LO694

Contractor
CHEMRAY COATING, CORP.
KENILWORTH, NJ 07033 US

Telephone: 201-245-1111

Cage: LO694

Ingredients

STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 29%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293


VOC=3.10 LBS/GAL OR 372 GRAMS/LITER

RTECS: 9999999VO

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Effects of Overexposure:OVEREXPOSURE-NAUSEA, HEADACHE, DIZZINESS CAUSED
BY OVER INHALATION.
Medical Cond Aggravated by Exposure:NONE GENERALLY KNOWN.

First Aid

First Aid:EYE CONTACT: FLUSH WITH WATER 15 MINUTES OR UNTIL IRRITATION
SUBSIDES. IF IRRITATION PERSISTS CALL A PHYSICIAN. SKIN CONTACT:
REMOVE CONTAMINATED CLOTHING AND WASH THOROUGHLY WITH SOAP AND
WATER. INHA LATION: IF OVERCOME BY VAPORS, REMOVE TO FRESH AIR,
CALL A PHYSICIAN. INGESTION: DO NOT INDUCE VOMITING, CALL A
PHYSICIAN.

Fire Fighting

Flash Point Method:SCC
Flash Point:103 F/40 C
Autoignition Temp:Autoignition Temp Text:473F
Lower Limits:0.9
Upper Limits:7
Extinguishing Media:CARBON DIOXIDE, FOAM, WATER FOG, DRY CHEMICAL
Fire Fighting Procedures:USE AIR SUPPLIED BREATHING EQUIPMENT. COOL
ENCLOSED CONTAINERS WITH WATER SPRAY. AVOID BREATHING VAPORS OR
FUMES.
Unusual Fire/Explosion Hazard:IF LEAK OR SPILL HAS IGNITED. USE WATER
SPRAY TO DISPERSE THE VAPORS FROM FIRE FIGHTERS.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNITION SOURCES. KEEP FROM HEAT,
SPARKS & OPEN FLAMES. ADD ABSORBENT(SAND,EARTH,SAWDUST)TO SPILL.
VENTILATE AREA(OPEN WINDOWS,DOORS). IF LARGE SPILL KEEP FROM
ENTERING SEWERS & WATERCOURSE S BY DIKING. ADVISE AUTHORITIES IF
PRODUCT ENTERS.

Handling

Handling and Storage Precautions:STORE AWAY FROM IGNITION SOURCES. KEEP
IN COOL, DRY, WELL VENTILATED AREAS. AVOID DIRECT SUNLIGHT AND
EXTREME TEMPERATURES, HOT OR COLD.
Other Precautions:AVOID EYE &/OR SKIN CONTACT, INHALATION &/OR
INGESTION OF MISTS, SPRAY OR VAPORS. AVOID BREATHING SANDING OR
BLASTING DUST.

Exposure Controls

Respiratory Protection:USE HYDROCARBON VAPOR CANISTER OR SUPPLIED AIR
RESPIRATOR IN CONFINED AREAS.
Ventilation:LOCAL EXHAUST-FACE VELOCITY 60FPM. SPECIAL-USE ONLY WITH
ADEQUATE VENTILATION. MECHANICAL-USE EXPLOSION PROOF EQUIPMENT.
Protective Gloves:CHEMICAL RESISTANT GLOVES
Eye Protection:SPLASH GOGGLES OR FACE SHIELD
Other Protective Equipment:USE CHEMICAL RESISTANT APRONS OR CLOTHING.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:308F,153C
Melt/Freeze Pt:M.P/F.P Text:0F,-18C
Decomp Temp:Decomp Text:600F/316C
Vapor Pres:<10 @ 68F
Vapor Density:4.8 @ 77F
Spec Gravity:1.34
Viscosity:77-89@77F KU
Evaporation Rate & Reference:0.09 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW LIQUID WITH KEROSENE ODOR.
Percent Volatiles by Volume:50.2

Stability

Stability Indicator/Materials to Avoid:YES
CAN REACT WITH OXIDIZING MATERIAL WHEN HEATED TO DECOMPOSITION.
Stability Condition to Avoid:HIGH TEMPERATURES
Hazardous Decomposition Products:CARBON MONOXIDE.

Disposal

Waste Disposal Methods:ASSURE CONFORMITY WITH APPLICABLE DISPOSAL
REGULATIONS. DISPOSE OF ABSORBED MATERIAL AT AN APPROVED DISPOSAL
SITE OR FACILITY. DISPOSE IN CONFORMITY WITH STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.